Viabilidad Celular

Reactivos para ensayos de viabilidad celular

  • Presentación: 100 ensayos (G9711) y 1000 ensayos (G9713).
  • Save time, cell culture and reagent costs.
  • Rapidly detect changes in cell viability
  • With the RealTime-Glo™ MT Cell Viability Assay, you can monitor cell viability continually in the same sample well out to 72 hours to obtain more information about the mode of action of a treatment with regard to time and dose dependence.
  • The assay reagent can be added to cells during plating, during treatment or at the end of treatment.
  • No cell washing, media removal or further additions are required.

  • Presentación: 10ml (G9241) y 100ml (G9242).
  • Reduced preparation time.
  • Convenient repeat use over multiple days.
  • Same great performance as classic CellTiter-Glo® Assay.
  • CellTiter-Glo® 2.0, based on the original CellTiter-Glo® Assay chemistry, is a single-reagent format with improved stability for convenient storage and simpler setup.







  • Presentación: 10ml (G9681) y 100ml (G9683).
  • Accurate 3D cytotoxicity determination
  • Easy assay implementation
  • Simple, 30-minute protocol
  • The CellTiter-Glo® 3D Cell Viability Assay is designed for determining cell viability in 3D microtissue spheroids.
  • The assay reagent penetrates large spheroids and has increased lytic capacity—allowing more accurate determination of viability compared to other assay methods.





  • Presentación: 10ml (G7570) y 100ml (G7572).
  • A Luminescent Assay to Determine the Number of Viable Cells in Culture.
  • A homogeneous “add-mix-measure” format reduces the number of steps.
  • Higher level of detection requires fewer cells per assay.
  • Process plates consecutively with a very stable luminescent signal.
  • Is a homogeneous method of determining the number of viable cells in culture based on quantitation of the ATP present, an indicator of metabolically active cells.

  • Presentación: 10ml (G6080) y 5x10ml (G6081).
  • A Non-Lytic Fluorescence Assay That Measures the Relative Number of Viable Cells in Culture.
  • Multiplex with many other luminescent assays.
  • Normalizing data for live-cell numbers make results more comparable to other data
  • The CellTiter-Fluor Cell Viability Assay is a non-lytic, single-reagent-addition fluorescence assay that measures the relative number of viable cells in a population.

  • Presentación: 20ml (G8080) y 100ml (G8081).
  • A Homogeneous, Fluorescent Assay to Monitor Cell Viability.
  • Fast, flexible, time-saving.
  • Amenable to multiplexing with other assaysA Non-Lytic Fluorescence Assay
  • The CellTiter-Blue® Cell Viability Assay provides a homogeneous, fluorescent method for monitoring cell viability.



Empresas

RealTime-Glo™ MT Cell Viability Assay

 

CellTiter-Glo® 2.0 Assay

 

CellTiter-Glo Luminescent Cell Viability Assay

 

CellTiter-Fluor™ Cell Viability Assay

 

CellTiter-Blue Cell Viability Assay